PROPELLER BULLETIN

Sensenich Propeller

SERVICE LETTER NO. 80-1

January 15, 1980

TO:

FAA APPROVED PROPELLER REPAIR STATIONS, SENSENICH CORPORATION DISTRIBUTORS

SUBJECT:

METAL PROPELLER INSTALLATION, ATTACHING BOLT WRENCH TORQUE


DISCUSSION:

(1) The wrench-torques recommended by Sensenich have traditionally been given in units of inch-pounds. It is possible that the torque may have been applied in foot-pounds without converting the torque units (1 ft-lb = 12 inch-pounds).

(2) The threads of the bolts may have been oiled, which decreases the friction force produced during the torquing operation and therefore increases the amount of pre-load in the bolt at a certain wrench torque.

RECOMMENDED ACTION:


GO TO Installation Instructions for Bolt Torque (Flange Shaft)
GO TO Installation Instructions for Bolt Torque (Lock Nuts)

Go Button Return to Miscellaneous Documents Menu
The Back to the Home Page Goto Button Return To Main Menu

You have been visiting: http://www.sensenich.com